- DENTAL MATERIALS
Ex vivo digital comparison of four impression techniques using an industrial laser scanner
DOI: https://doi.org/10.25241/stomaeduj.2022.9(1).art.2
Bálint Jász1a*, Máté Jász1b, Szandra Körmendi1c, Gellért Joós-Kovács1d, Bálint Vecsei1e, Péter Hermann1f, Judit Borbély1g
1Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi utca 47, HU-1088 Budapest, Hungary
aDMD, Clinical Doctor; e-mail: jasz.balint@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0002-5556-137X
bMD, DMD, Assistant Professor; e-mail: jasz.mate@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0002-6717-5126
cDMD, Assistant Professor; e-mail: kormendi.szandra@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0003-4694-1342
dDMD, Assistant Professor; e-mail: joos-kovacs.gellert_levente@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0002-0522-3751
eDMD, Assistant Professor; e-mail: vecsei.balint@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0001-5748-7276
fDMD, PhD, MSc, Professor and Head; e-mail: hermann.peter@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0002-9148-0139
gDMD, PhD, Associate Professor; e-mail: borbely.judit@dent.semmelweis-univ.hu; ORCIDiD: https://orcid.org/0000-0003-3064-8724
Abstract
Introduction The aim of the study was to compare different impression techniques used for fixed prosthodontics.
Methodology A master cast with prepared abutments was created from polymethyl-methacrylate (PMMA). A high-resolution industrial scanner was used to create a virtual reference model. Four different impressions were made, three with polyvinyl-siloxane (PVS) (n = 10 for each): one-step putty-wash (1SPW), two-step putty-wash prepared with an escape channel (2SPW-Ch), two-step putty-wash with a polyethylene spacer foil (2SPW-Fo), and one with polyether monophasic technique (MP) from the PMMA model and digitized with an industrial scanner. The stereolithographic (STL) files of the impressions (n = 40) were exported. Each file was compared to the reference using the Geomagic Verify software. Six points were assigned to enable virtual calliper measurement of tooth diameters and distances of varying sizes within the arch.
Results In the case of die diameters, the deviation from the mould ranged from 31.84 to 180.64 µm. At the stump diameter level, the MP and 1SPW techniques showed significantly more minor differences than the 2SPW-Ch, and the MP was significantly more accurate than the 2SPW-Fo. At medium distance, the deviation ranged from 42.74 to 136.47 µm. Therefore, MP was found to be significantly more accurate than 2SPW-Ch. When examining the long distance, the difference was between 162.62 and 348.85 µm. The MP and 1SPW impression techniques proved significantly more accurate than the 2SPW-Ch technique for long distances.
Conclusions With both simultaneous techniques, significantly more true results were achieved than with the two-step techniques.
Keywords
Dental Impression Technique; Scanning of the Impression; Monophase; One-Step Putty-Wash; Two-Step Putty-Wash.
1. Introduction
One of the most critical steps in our dental processes is to make impressions with reasonable accuracy. The impression allows the dental technician to have the same condition on the model as in the patient’s mouth. When examining impressions, trueness and precision can be examined, and these two together constitute accuracy. ISO 5725 uses two terms, trueness and precision, to describe the accuracy of a measurement method. Trueness refers to the closeness of agreement between the arithmetic mean of a large number of test results and the true or accepted reference value. Meanwhile, precision refers to the closeness of agreement between test results [1]. In this study, only the trueness of the impressions was examined. A review article published in 2016 defined the still tolerable inaccuracy in the crown’s fit between 50 and 200 µm after the turn of the millennium [2]. The article by McLean and von Fraunhofer from 1972, which is still frequently cited, gives the 120-micron deviation as an inaccuracy threshold, so this level of accuracy must be aimed at for impressions [3-5].
According to the ISO standard, which currently regulates the properties of elastic impression materials, the kneadable material with the lowest reproducibility must have a resolution of at least 75 µm, so there is no material scientific obstacle to achieving this trueness and accuracy [6]. Therefore, in addition to the spread of digital dentistry, information on the trueness of traditional impression techniques remains of paramount importance. The reason for this is twofold. On the one hand, the digitization of conventional impressions or models is one of the possible routes to CAD / CAM techniques; on the other hand, the vast majority of dental offices still use traditional impressions [7,8]. In addition, numerous studies and factory data are available on the impression materials themselves and their accuracy [9]. However, the trueness and accuracy of the various impression techniques are still not widely researched. Most in vitro examinations of impressions use simplified bodies, such as cones instead of teeth or tooth models [10,11]. In many studies, only two or three techniques are compared in an analogous way or by the evaluation of trained clinicians, but not in a qualitative way [12-14]. In the present in vitro study using a PMMA master cast with prepared stumps, the four most commonly used precision impression techniques are compared to explore whether there was a difference in the sampling trueness of these techniques. The hypothesis is that one-step impression techniques are truer than two-step techniques.
2. Methodology
The following four impression techniques are examined in the present study:
• the one-step putty-wash technique (1SPW),
• the monophase technique (MP),
• the two-step putty-wash technique prepared with escape channels (2SPW-Ch), and
• the two-step putty-wash technique prepared with a polyethylene spacer foil (2SPW-Fo).
Ten impressions were taken from a PMMA master model using each technique, i.e., altogether 40 impressions were created [15,16]. On the upper jaw master model, supragingival, chamfer shoulder preparation of the right first premolar (14), left first incisor (21), first premolar (24), and second molar (27) were prepared. In all cases, the impressions were made considering the manufacturer’s instructions, the literature recommendations, and consensus [11,17,18]. Impression materials with the recommended consistency for the impression technique were applied in all cases, as stated in the factory recommendation [18]. For the 1SPW technique, a metal stock impression tray was used, with ISO-1 (Express XT Penta H; 3M ESPE), and ISO-3 consistency (Express XT Light Body; 3M ESPE) polyvinylsiloxane (PVS) impression material. The tray was filled with heavy-bodied material, its entire surface was covered with the wash material, and on all of the prepared teeth, an impression syringe was used to inject the wash material [15]. For the MP technique, a custom-made tray prepared by the dental technician from Lightplast Baseplate (Dreve-Dentamid, Unna, Germany) and ISO-2 consistency polyether impression material (Impregum Penta Soft; 3M ESPE) were used [19]. For the proper adhesion of the impression material to the tray, the Polyether Adhesive (3M ESPE) was applied as required by the manufacturer. The mixed impression material was filled into the tray, and all the prepared stumps were injected with an impression syringe.
A metal stock tray and ISO-0 putty consistency PVS impression material (Express XT Penta Putty; 3M ESPE) were used for the two-time impressions, followed by ISO-3 consistency PVS wash material (Express XT Light Body; 3M ESPE). Two different techniques were applied to ensure decompression. In the first case, escape channels were cut in the impression on both mesial and distal sides of each prepared tooth while alternating on the oral and buccal sides of the non-prepared teeth (2SPW-Ch) [16]. In the second case, the surface of the putty material was covered with a polyethylene spacer foil (Impression Separation Wafer GC Europe) to provide the proper gap for the wash material (2SPW-Fo) [20]. In all cases, the impression materials were mixed with the impression mixing machine as recommended by the manufacturer (Pentamix; 3M ESPE) or with a factory impression gun (Garant; 3M ESPE) following the manufacturer’s instructions [21].
A PMMA master model was applied in the study because its material did not affect the setting of the materials used in any way. As the model is durable, many impressions could be taken without distortion or change. To the best of our knowledge, the model itself did not affect the results of this study in any way [7,22]. The impression-taking procedure was standardized using a Kaán impression tool [23]. Each tray was filled with impression material to the edge of the impression tray. The same 3 kg weights were used at all impressions. At the Kaán tool, you can position the cast only in one way accordingly. The directions and extent of the force were the same at all impressions, thus standardizing the impression conditions (Fig. 1). The impressions were taken by one calibrated person.
In the first step, the master model was scanned by an industrial dot laser scanner (Two Scan; Varinex Informatikai Zrt., Budapest, Hungary), and then the forty prints were scanned as well [24]. As previously recommended, a minimum of 1, a maximum of 24 hours elapsed between the impressions being completed and the scan [25]. After scanning the impressions, the resulting .stl files had to be compiled to allow comparison of the data set with the data set obtained during the master model scan [26].
During the measurement, an incision plane was determined in the virtual space manually, which intersected all the prepared teeth examined. The reference points were determined automatically. The program selected points that could be used as reference points. Both the plane and the reference points were determined only once and were transferred between each measurement. The distances between measurement points were selected on the master model scan to establish the baseline data. Then the corresponding distances on each impression scan were measured and compared to the baseline (Software: Geomagic Verify, Geomagic Inc., Morrisville, NC, USA).
The mesiodistal (MD) and bucco-palatal (BP) diameters of the prepared teeth 14, 21, 24, 27 were measured in the incision plane. Furthermore, distances between 24 distal (24D) and 27 mesial (27M) measuring points (20 mm small distance), between the 24 mesial (24M) and 27 distal (27D) measurement points (32 mm medium distance), and 52 mm large distance between 21 mesial (21M) and 27D were measured [13,27]. GraphPad Prism 5 Software (GraphPad Software Inc., San Diego, CA, USA) was used for statistical analysis. The Kruskal–Wallis Test and Dunn’s multiple comparison post-hoc test were applied to examine the correlation between groups, with a significance threshold of
p < 0.05.
3. Results
Thus, six stump diameters (14BP, 21MD, 24BP, 24MD, 27BP, 27MD) and two distances (medium distance between 24M–27D and large distance between 21M–27D) were analyzed further (Fig. 2). Since the diameters of the stumps fell in the same size range, a common average of the six stump diameters was calculated for better statistical processability. Furthermore, only six instead of the originally planned eight diameters and two instead of three distances were examined. The problem arose when selecting the incision plane: some of the measuring points were in an area with undercuts during the scan. This is a problem, because in the invisible regions, the computer-calculated data were displayed partially, which significantly distorted the measurement results [28]. Therefore, the study did not consider the apparently false results between the 14 MD diameter and the 21 BP diameter and 24D–27M (short distance) [29].
The mean deviation for the six stump diameters was 31.84 µm for the MP impression technique (SD: 28.29), 56.48 µm for the 1SPW (SD 89.07), 74.04 µm for the 2SPW-Fo (SD 157.51), and in the case of 2SPW-Ch, it was 180.64 µm (SD 338.17). Examining the trueness of the stump sampling, we can observe the following trend: the truest was the MP technique followed by 1SPW, 2SPW-Fo, and finally the 2SPW-Ch. In terms of die diameters, MP was significantly truer than 2SPW-Fo and 2SPW-Ch, while 1SPW was significantly truer than 2SPW-Ch. The other differences were statistically not significant (Fig. 3).
For the medium distance between 24M and 27D, the trend was the same as found at the level of the stumps. The MP technique proved to be the truest; the deviation from the sample was 42.74 µm (SD: 31.22), followed by 1SPW 71.37 µm (SD: 53.67), 2SPW-Fo 83.46 µm (SD: 57.25), and then 2SPW-Ch 136.47 µm (SD: 61.57). A significant difference was found only between MP and 2SPW-Ch. The other differences were not significant statistically (Fig. 4).
For the large distance between 21M and 27D, the trueness was as follows: the slightest deviation, 162.62 µm (SD: 68.24), was found for 1SPW. This was followed by MP 188.32 µm (SD: 48.48), 2SPW-Fo 286.14 µm (SD: 174.18), and finally 2SPW-Ch 348.85 µm (SD: 122.68). For the 2SPW-Ch technique, both 1SPW and MP proved significantly truer (Fig. 5).
4. Discussion
Regarding the sampling trueness of the impressions, the strict deviation of 50 µm only fits the diameters of the stumps, and the medium distance measured between 24M and 27D with the MP impression technique [2]. The trueness of 1SPW with 2SPW-Fo techniques fell outside this range but is well within the most generally accepted trueness of 120 µm for both distances mentioned above [3]. The sampling trueness of the 2SPW-Ch technique shows a difference of more than 120 µm, even in the case of the stump diameter. The distance measured between the stumps increases even more with the increase of the examined length. Concerning long distance, the degree of deviation from the initial sample remained below 200 µm in the case of the 1SPW and the MP techniques, while for the 2SPW-Fo technique, it almost reached 300 µm. However, it does not make sense to use the 120 µm deviation for medium and long distances, since the distances examined are larger by orders of magnitude than for stump diameters. In this case, it is better to express the extent of the deviation in proportion to the distance examined (Table 1).
Thus, for all the examined distances, except for the largest studied length, the MP technique showed the slightest difference, followed by the 1SPW and the 2SPW-Fo methods, and in all cases, the 2SPW-Ch technique performed the worst. The first and second places were reversed for the largest distance examined.
Pastoret et al. found that the 1SPW technique performed best for short distances, while the MP technique performed best the long distances, but in both cases, the 2SPW-Fo technique remained below them [17]. Rudolph et al. and Luthardt et al. established the order 1SPW, MP, 2SPW with a spacer cap, while Dugal et al. found the 1SPW technique to be more accurate than the 2SPW with spacer cap [13,18,30]. According to Mann et al., the 2SPW-Fo impression technique is more accurate than the 2SPW-Ch technique [16]. These findings are all in accordance with the results published here.
Contrarily, Caputi et al. found a unique 3-phase impression technique to be the most accurate, followed by the 1SPW, and finally, the MP techniques [31]. The discrepancy may be that the MP technique was used with PVS and a stock tray instead of polyether and a custom tray. Nissan et al. found the latter to be the most accurate in both studies when comparing techniques using 1SPW, 2SPW-Fo, and 2SPW with a spacer cap [11,20]. The third technique, which was not examined in the present study, proved to be the most accurate. However, Nissan et al. did not succeed in detecting a significant difference between the 1SPW and the 2SPW-Fo techniques they examined, which coincides with the results presented here. In his study, Nissan used the same ISO 0, putty consistency impression material for all three techniques, which is not ideal for the 1SPW technique. This may be partially responsible for the different results. Jamshidi et al. found the 2SPW-Ch technique significantly more accurate than the 1SPW technique. However, in the one-step technique, the wash material was injected only on the stumps, they did not cover the kneadable base, and both techniques had the same ISO 0 consistency [12].
In the most relevant literature, the simultaneous techniques proved to be more accurate, i.e., less difference can be expected when using them than in the case of separate time impression techniques, except for some less commonly used, individually modified two-step techniques [17,30]. In almost all studies examining two-step techniques, using the 2SPW-Fo technique or 2SPW with spacer cap gave better results than the 2SPW-Ch method [11,16]. All this is in line with the results presented here.
However, there is no consensus on which simul-taneous technique provides greater trueness: MP or 1SPW? One important reason for the discrepancy may be that the combinations of impression material and impression tray recommended primarily for the 1SPW and MP techniques were not appropriately used in all studies [11,12,31]. As is well known, the 1SPW impression technique is primarily based on ISO 1 consistency (and not ISO 0, as in several of the studies cited), and a stock tray is recommended. In contrast, for the MP technique, the use of ISO 2 medium consistency material and a custom tray gives the best result [18]. In the latter case, polyether impression material has an advantage over PVS due to its thixotropic effect.
According to our study results, it can be said that the one-step impression techniques performed better. This may be due to the deformation during the replacement of the impression for the second time. Additionally, the hydraulic distortion, and finally the imperfect connection between the two different consistencies at the two-step impression techniques may account for the better performance of one-step techniques.
Within the limitations of this study, it can be concluded that better clinical results can be achieved using one-step impression techniques, either MP or 1SPW, while preparing fixed prostheses. In the case of using the two-step putty-wash technique, the decompression with only escape channels might be insufficient, leading to hydraulic distortion and inaccurately sitting fixed prosthesis in the end. However, it is essential to note that besides the MP and the 1SPW impression techniques, even the 2SPW-Fo method provides adequate results at the stump level, only 2SPW-Ch proved to be insufficient this level.
5. Conclusion
Within the limitations of this study, the hypothesis was confirmed: it was proved that the MP and the 1SPW, i.e., the simultaneous techniques, showed significantly better trueness among the examined precision impression techniques. In contrast, the 2SPW-Ch technique proved to be the most inaccurate at all diameters and distances.
CONFLICT OF INTEREST
The authors have no financial interest in any of the companies whose products are used in this study.
Author Contributions
BJ, SZK, MJ and JB: concept. SZK, BV, GJK: protocol. BJ, SZK, MJ, BV, GJK: data gathered and analyzed. PH, JB: interpretated and critically revised the manuscript. All authors read and approved the final manuscript.
REFERENCES
1. ISO 5725-4:2020. Accuracy (trueness and precision) of measurement methods and results – Part 4: Basic methods for the determination of the trueness of a standard measurement method, 2020, p. 2.
2. Ahlholm P, Sipilä K, Vallittu P, et al. Digital versus conventional impressions in fixed prosthodontics: a review. J Prosthodont. 2018 Jan;27(1):35-41. doi: 10.1111/jopr.12527. PMID: 27483210.
Full text links CrossRef PubMed Google Scholar Scopus WoS
3. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971 Aug 3;131(3):107-111. doi: 10.1038/sj.bdj.4802708. PMID: 5283545.
Full text links CrossRef PubMed Google Scholar Scopus WoS
4. Tsirogiannis P, Reissmann DR, Heydecke G. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis. J Prosthet Dent. 2016 Sep;116(3):328-335.e2. doi: 10.1016/j.prosdent.2016.01.028. PMID: 27061627.
Full text links CrossRef PubMed Google Scholar Scopus WoS
5. Hasanzade M, Shirani M, Afrashtehfar KI, et al. In vivo and in vitro comparison of internal and marginal fit of digital and conventional impressions for full-coverage fixed restorations: a systematic review and meta-analysis. J Evid Based Dent Pract. 2019 Sep;19(3):236-254. doi: 10.1016/j.jebdp.2019.04.003. PMID: 31732100.
Full text links CrossRef PubMed Google Scholar Scopus WoS
6. ISO 4823:2015. Dentistry – Elastomeric impression materials, 2015, p. 39.
7. Joós-Kovács G, Vecsei B, Körmendi S, et al. Trueness of CAD/CAM digitization with a desktop scanner – an in vitro study. BMC Oral Health. 2019 Dec 12;19(1):280. doi: 10.1186/s12903-019-0976-1. PMID: 31830970; PMCID: PMC6909471.
Full text links CrossRef PubMed Google Scholar Scopus
8. Sailer I, Mühlemann S, Fehmer V, et al. Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part I: Time efficiency of complete-arch digital scans versus conventional impressions. J Prosthet Dent. 2019 Jan;121(1):69-75. doi: 10.1016/
j.prosdent.2018.04.021. PMID: 30017152.
Full text links CrossRef PubMed Google Scholar Scopus WoS
9. Bajoghli F, Sabouhi M, Nosouhian S, et al. Comparing the accuracy of three different impression materials in making duplicate dies. J Int Oral Health. 2015 Jul;7(7):12-16. PMID: 26229364; PMCID: PMC4513764.
Full text links PubMed Google Scholar
10. Haralur SB, Saad Toman M, Ali Al-Shahrani A, Ali Al-Qarni A. Accuracy of multiple pour cast from various elastomer impression methods. Int J Dent. 2016;2016:7414737. doi: 10.1155/2016/7414737. PMID: 28096815; PMCID: PMC5206852.
Full text links CrossRef PubMed Google Scholar WoS
11. Nissan J, Rosner O, Bukhari MA, et al. Effect of various putty-wash impression techniques on marginal fit of cast crowns. Int J Periodontics Restorative Dent. 2013 Jan-Feb;33(1):e37-e42. doi: 10.11607/prd.0713. PMID: 23342356.
Full text links CrossRef PubMed Google Scholar Scopus WoS
12. Jamshidy L, Mozaffari HR, Faraji P, Sharifi R. Accuracy of the one-stage and two-stage impression techniques: a comparative analysis. Int J Dent. 2016;2016:7256496. doi: 10.1155/2016/7256496. PMID: 28003824; PMCID: PMC5143723.
Full text links CrossRef PubMed Google Scholar Scopus
13. Dugal R, Railkar B, Musani S. Comparative evaluation of
dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. J Int Oral Health. 2013 Oct;5(5):85-94. PMID: 24324310; PMCID: PMC3845290.
Full text links CrossRef PubMed Google Scholar
14. Dogan S, Schwedhelm ER, Heindl H, et al. Clinical efficacy of polyvinyl siloxane impression materials using the one-step two-viscosity impression technique. J Prosthet Dent. 2015 Aug;114(2):217-222. doi: 10.1016/j.prosdent.2015.03.019. PMID: 25976708.
Full text links CrossRef PubMed Google Scholar Scopus WoS
15. Varvara G, Murmura G, Sinjari B, et al. Evaluation of
defects in surface detail for monophase, 2-phase, and 3-phase impression techniques: an in vitro study. J Prosthet Dent. 2015 Feb;113(2):108-113. doi: 10.1016/j.prosdent.2014.08.007. PMID: 25438741.
Full text links CrossRef PubMed Google Scholar Scopus WoS
16. Mann K, Davids A, Range U, et al. Experimental study on the use of spacer foils in two-step putty and wash impression
procedures using silicone impression materials. J Prosthet Dent. 2015 Apr;113(4):316-322. doi: 10.1016/j.prosdent.2014.09.014. PMID: 25453563.
Full text links PubMed Google Scholar Scopus WoS
17. Pastoret MH, Krastl G, Bühler J, et al. Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique. J Adv Prosthodont. 2017 Aug;9(4):287-293. doi: 10.4047/jap.2017.9.4.287. PMID: 28874996; PMCID: PMC5582095.
Full text links PubMed Google Scholar Scopus WoS
18. Rudolph H, Graf MR, Kuhn K, et al. Performance of dental impression materials: benchmarking of materials and techniques by three-dimensional analysis. Dent Mater J. 2015;34(5):572-584. doi: 10.4012/dmj.2014-197. PMID: 25948142.
Full text links CrossRef PubMed Google Scholar Scopus WoS
19. Endo T, Finger WJ. Dimensional accuracy of a new polyether impression material. Quintessence Int. 2006 Jan;37(1):47-51. PMID: 16429703.
Full text links PubMed Google Scholar WoS
20. Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000 Feb;83(2):161-165. doi: 10.1016/s0022-3913(00)80007-4. PMID: 10668027.
Full text links PubMed Google Scholar Scopus WoS
21. Punj A, Bompolaki D, Garaicoa J. Dental impression materials and techniques. Dent Clin North Am. 2017 Oct;61(4):779-796. doi: 10.1016/j.cden.2017.06.004. PMID: 28886768.
Full text links PubMed Google Scholar
22. Vecsei B, Joós-Kovács G, Borbély J, Hermann P. Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD/CAM systems – an in vitro study. J Prosthodont Res. 2017 Apr;61(2):177-184. doi: 10.1016/j.jpor.2016.07.001. PMID: 27461088.
Full text links PubMed Google Scholar Scopus
23. Kaán BF K, Somogyi E, Kaán M, Fejérdy P. An examination of the modelling ability of two-time two-phase silicon impression taking procedures, with a specially designed tool and method. Hungarian Dental Association Árkövy Conference, Word Dental Congress, Vienna, 2002.
24. Ender A, Mehl A. Accuracy of complete-arch dental
impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013 Feb;109(2):121-128. doi: 10.1016/S0022-3913(13)60028-1. PMID: 23395338.
Full text links PubMed Google Scholar Scopus WoS
25. Gonçalves FS, Popoff DA, Castro CD, et al. Dimensional
stability of elastomeric impression materials: a critical review of the literature. Eur J Prosthodont Restor Dent. 2011 Dec;19(4):163-166. PMID: 22645802.
26. Ender A, Mehl A. Full arch scans: conventional versus digital impressions–an in-vitro study. Int J Comput Dent. 2011;14(1):11-21. English, German. PMID: 21657122.
Full text links PubMed Google Scholar Scopus
27. Vitti RP, da Silva MA, Consani RL, Sinhoreti MA. Dimensional accuracy of stone casts made from silicone-based impression materials and three impression techniques. Braz Dent J. 2013 Sep-Oct;24(5):498-502. doi: 10.1590/0103-6440201302334. PMID: 24474292.
Full text links PubMed Google Scholar Scopus
28. Ender A, Zimmermann M, Attin T, Mehl A. In vivo precision of conventional and digital methods for obtaining quadrant dental impressions. Clin Oral Investig. 2016 Sep;20(7):1495-1504. doi: 10.1007/s00784-015-1641-y. PMID: 26547869.
Full text links CrossRef PubMed Google Scholar Scopus WoS
29. Haim M, Luthardt RG, Rudolph H, et al. Randomized controlled clinical study on the accuracy of two-stage
putty-and-wash impression materials. Int J Prosthodont. 2009 May-Jun;22(3):296-302. PMID: 19548415.
CrossRef PubMed Google Scholar Scopus WoS
30. Luthardt RG, Walter MH, Quaas S, et al. Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial. Quintessence Int. 2010 Nov-Dec;41(10):845-853. PMID: 20927421.
Full text links PubMed Google Scholar Scopus WoS
31. Caputi S, Varvara G. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel
two-step putty/light-body impression technique: an in vitro
study. J Prosthet Dent. 2008 Apr;99(4):274-281. doi: 10.1016/S0022-3913(08)60061-X. PMID: 18395537.
Figures are shown in pdf document
| (read pdf) |