doi.org/10.25241/stomaeduj.2018.5(4).art.4

  • RESTORATIVE DENTISTRY

Light curing matters: Facts often overseen by dentists

DOI: https://doi.org/10.25241/stomaeduj.2018.5(4).art.4

Authors:
Dayane Carvalho Ramos Salles de OliveiraORCIDiD | Publons | ResearchGate | CrossRef | PubMed | Google Scholar | Scopus | WoS
Mateus Garcia RochaORCIDiD | Publons | ResearchGate | CrossRef | PubMed | Google Scholar | Scopus | WoS
Jean-François RouletORCIDiD | Publons | ResearchGate | | CrossRef | PubMed | Google Scholar | Scopus | WoS

 

  1. Introduction

When placing a restoration, dentists are mainly performing a manufacturing process. This presumes good equipment, materials and process techniques. This short article will focus on the latter. A prerequisite for a proper functionality of a resin composite restoration in the oral cavity [1] is to receive sufficient radiant exposure (= irradiance of the light curing unit x exposure time).

In advertisements, light curing units (LCU) are usually characterized by their irradiance, which is expressed in mW/cm2. This parameter alone is, however, by far insufficient to assess the quality of light curing. It should be mentioned that currently, the range of prices for dental LCUs varies among $18.59 (best-selling offer on e-bay on December 3rd 2018) and even more than $1000. While the irradiance of low-cost and expensive LCUs may be comparable, the price difference is reflected in the homogeneity of the light beam, the diameter of the light exiting window, the collimation of the light beam, the battery management to deliver a constant radiant exposure over time (Fig. 1). Saving on the cost of a light curing unit is saving on the wrong side. It should be emphasized here that, related to the total costs of a resin composite restoration, the use of an expensive LCU does not exceed 1%. This investment is worth, considering that the use of a deficient LCU may result in a poorly polymerized resin composite restoration, while the materials used will not perform as intended by the manufacturer.

Generally, manufacturers clearly indicate the radiant exposure necessary to adequately polymerize their materials (e.g. 20 seconds at 800 mW/cm2). However, a fact that is often forgotten by dentists is to take into account the incremental thickness of the applied resin composites. Resin composites absorb, reflect and scatter the light they receive during polymerization. This means that if the maximum recommended incremental thickness is exceeded, the polymerization of the material may be insufficient, with the consequences described above. The incremental thickness recommended for most regular resin composites is 2 mm, while for bulk fil resin composites it may be extended to 4-5 mm. It should be emphasized that darker shades and less translucent resin composites will absorb more light and show a reduced depth of cure (= incremental thickness that is adequately cured) [2].

Besides the above-mentioned reasons, the success of resin composite restorations depends on further factors [3], while the less known and most neglected factor is the light curing process [4-6]. Resin composite restorations increasingly fail due to marginal failures [7,8], as evidenced especially in Cass II restorations, which might be found in periodical x-rays (Fig. 2). What the majority of dentists do not know is that the most common reason for this kind of marginal breakdown is inadequate light curing [9].

It is nowadays well-documented that there is a large variation between operators in delivering the radiant exposure during the light curing process of a resin composite restoration. The use of an efficient LCU is therefore not a guarantor for an adequate polymerization [5,9-11]. Fortunately, education associated with proper training was proved to be efficient to improve light curing skills (Fig. 3) [9-11].

 

  1. Clinical aspects

The first important factor that can lead to improper light curing is not paying attention [9-11]. Modern curing lights emit irradiances above 1000 mW/cm2 [12],  thus looking into the light during polymerization is not recommended  due to potential risk for ocular hazards [13-15]. In response to that, most dentists avoid looking to the patient’s mouth during the light curing process. 

 

2.1. Blue-blocking filters

The right way to properly cure a restoration is positioning the light tip as close as possible and parallel to the restoration and stabilize and maintain it throughout the exposure [15]. In order to do so, some kind of blue-blocking shield is extremally needful. Different kinds of orange filters are available in the market to provide protection to the eyes during the light curing process (Fig. 4). These filters are able to block at least 97% of the light emitted from dental curing lights [16]. As can be observed in Fig. 5, the radiant emittance from the curing light is 1000 mW/cm2, however, after interposing a blue-block filter in between the curing light emission and the sensor, the irradiance emittance from the curing light is totally blocked. It is worthwhile  mentioning that while using magnification loupes, the irradiance received at the pupil can be increased by up to 8 times greater than when no loupes are used
(Fig. 6) [13]. Despite almost no publicity even from the own brands, blue-blocking filters specially made for loupes are available in the market, as previously illustrated in Fig. 3.

 

2.2. Positioning

The ideal case scenario is to light cure positioning the light tip as close as possible and parallel to the restoration during light curing [15]. However, different clinical situations can make this difficult or almost impossible, such as the restauration location and the light tip angulation versus patient mouth aperture (Fig. 7) [17,18]. 

Another aspect that cannot be neglected is that different curing lights have different light tip sizes. The light tip diameter of the curing lights in the market are between 7 and 12 mm [19,20]. Usually fiber optic guides vary from 7 to 9 mm in diameter [19], while quartz lenses such as used in the VALO Cordless and VALO Grand (Ultradent, South Jordan, UT, USA) are 10 and 12 mm in diameter, respectively [19,20]. Usually pre-molar are about 7 mm wide, but average molars are about 10 mm wide (Fig. 8) [21]. Thus, special attention in positioning the curing light is encouraged when light curing proximal boxes in Class II restorations, as well as two light curing procedures in each end (mesial and distal) while using bulk fill composites in Class II restorations (Fig. 9) [4,6,15].

When the light tip is not positioned properly, either because of limitations due to its size (Fig. 8) or because of angulations caused by mouth aperture (Fig. 10), not enough light will reach the resin material and polymerization can be affected [15], especially in depth, possible causing marginal breakdowns such as exemplified in Fig. 1.

2.3. Cleaning and maintaining

Finally, leaning and maintaining should not be forgotten. It is already known that broken and dirty light curing tips can affect the polymerization of the material [15]. Usually, when the light tip gets in direct contact with the resin composite or adhesive during polymerization, part of this material adheres to the light tip. The problem is that not only does the restoration lose shape because part of the resin material is transferred to the light tip, but the next increment of resin will not receive the same radiant exposure than the first one. Light curing sleeves are not only able to protect from cross-contamination, but the light tip from resin material adhesion when accidental contact is made with the restoration during the light curing process. It is known that using light curing sleeves can cause a small reduction in the irradiance emittance from the curing light, but it is already proven not to influence on polymerization [22]. Fig. 11 illustrates an exemplification of the drop in the irradiance emittance from a curing light when no barrier sleeve is used and the light tip is clean, when the light tip is dirty and when a barrier sleeve is used. Of course, using a barrier sleeve is extremally important to protect the light tip, and guarantee proper polymerization. 

 

  1. Conclusions

To conclude this topic, it is worthwhile mentioning that several studies have demonstrated that the education provided to dentists and dental students seems to be insufficient to teach them how to deliver the proper amount of radiant exposure from a curing light to the restoration [9-11]. On the other hand, education associated with proper training was proved to be efficient to improve light curing skills, even in short training sessions [9-11]. Educational institutes and professors shall reinforce proper light curing techniques and associate training sessions within educational courses in order to improve teaching and learning. 

 

Author Contributions

DO: written and proofread the manuscript. 

MR: written and proofread the manuscript. 

JFR: written and proofread the manuscript.

 

 